Bearing Tool - Bearing Change Instructions

Suitable for SMF-200-R1


Step 1
- Unplug power and roll machine on side. Remove pad.


Step 2
- Remove PVC disc (p/no. 9903059) from base plate.

Step 3
- Remove base plate (p/no. 9903018) from assembly.


Step 4
- Remove assembly from motor hub (p/no. 9903011).

Step 5
- Remove 3 weights from assembly.

Step 6
- Press pivot pin (p/no. 9903017) from assembly to release bearing and retainer.

Step 7 - Remove bearing (p/no. 9903064) from retainer (p/no. 9903015).


Step 8 - Press new bearing into retainer as shown.


Step 9
- Press pivot pin (p/no. 9903017) into bearing as shown.

Step 10
- Remove hex bolt from jig. Place main plate (p/no. 9903012) on jig as shown and replace M6X16 screw and spacer (p/no. 9903014) before pressing.

Step 11 - Press together and be sure pivot pin is all the way in.

Step 12 - Use hex bolt to remove assembly off jig.